Case analysis offlue gas treatment project by SNCR-hydrogen peroxide oxidation denitration

Received Date:2020-12-03

Download Download 2021 NO.03

    Abstract:In order to solve excessive NOx emission of the grate-rotary kiln flue gas from a 600000 tons oxidized pelletizing produ... Open+
    Abstract:

    In order to solve excessive NOx emission of the grate-rotary kiln flue gas from a 600000 tons oxidized pelletizing production line, SNCR + hydrogen peroxide oxidation denitration was used to upgrade the process and realize the ultra-low emission of flue gas. The treatment capacity of the flue gas in this project was 400000 m3/h. The total investment of the denitration system was about 1.8 million, and the annual operating cost was 1.8946 million.The operation results showed that the concentration of NOx was reduced from 100 mg/Nm3 to 45 mg/Nm3, which was lower than the NOx emission limit (50mg/Nm3) of Shandong provincial local standard (DB 37/990—2019) and realize the ultra-low NOx emission.

    Close-

    Authors:

    • HUANG Jiayun
    • ZHU Ping*
    • XU Zhichao
    • ZHANG Xu
    • CHEN Haiwen

    Units

    • Wuhan Long King Environmental Technology Co., Ltd., Wuhan 430205, China

    Keywords

    • Flue gas denitration
    • Selective non catalytic reduction
    • Hydrogen peroxide oxidation denitration
    • Ultra low emission

    Citation

    HUANG Jiayun, ZHU Ping, XU Zhichao, et al. Case analysis of flue gas treatment project by SNCR-hydrogen peroxide oxidation denitration[J]. Energy Environmental Protection, 2021, 35(3): 60-65.

    Relate Article

    Add: No.288, Gongxiu Road, Xiaoshan District, Hangzhou City, Zhejiang Province.
    Post Code: 311201
    Tel: 0571-82989702, 19558121964
    E-mail: office@eep1987.com
    Website Copyright © Editorial Department of Energy Environmental Protection 京ICP备05086979号